USA PROJECTSPool permit and construction drawings
USA / COMMERCIAL POOL PLAN-REVIEW DRAWINGS

Public pool plan-review drawings.
Drawn for your engineer of record.

In states such as Washington and South Carolina, a hotel, HOA or other public pool needs its plans reviewed and approved by a state or local agency before construction. Your engineer or architect of record sets the design. We draft the sheets the reviewer asks for from that design and the agency’s checklist, and deliver them as DWG and PDF files.

DWG + PDF · Seal not included

JEBN
Drafts the set
File delivery
DWG + PDF
Engineer’s seal
Not included

Delivery time depends on the scope. Your quote states the delivery date.

Your contact: Benatic Paul Martin
JEBN Engineering LLC · benatic@jebnengineering.com
About JEBN Engineering LLC

SAMPLE DRAWINGS

Sample drawing sets.

Sheets from two drawing sets. Client and site names are removed and each sheet is marked VOID. Select a picture to see the sheet larger, then step through the set.

  • Longitudinal section through the spa and pool shell
  • Pool and spa plumbing routing plan with pipe runs in color
  • Isometric view of the pool equipment and pipework
POOL AND SPA SET · 7 SHEETS

Skimmer pool and spa on a lakeside lot

Pool and spa plan with pile layout, sections and details, plumbing routing, electrical layout, spa and filtration schematics and fitting details. Sample, not for construction.

View all 7 sheets →
Sheet list
  1. P-01 Pool and spa plan, pile layout
  2. P-02 Pool sections and details
  3. P-03 Pool and spa plumbing routing
  4. P-04 Pool electrical layout
  5. P-05 Spa plumbing schematic and isometric
  6. P-06 Pool plumbing and filtration schematic
  7. P-07 Pool fitting and fixing details
  • Layout plan of the two-tier fountain
  • Section through the fountain basins, walls and foundation
  • 3D view of the fountain on the entrance island

Project preview

Open full image in a new tab
YOUR DRAWING PACKAGE

What a plan-review set shows.

Each agency sets its own list, so the sheet list follows your state’s rule and the reviewer’s checklist. This list of parts comes from the state rules and the CDC model code cited below.

Request a full package or help with existing plans.

Get a quote for this set →
  1. Site plan

    The pool on the property, with nearby buildings, walkways, utilities and the equipment room. Some rules also ask for water, sewer and drainage locations on this sheet.

  2. Pool plan and sections

    A dimensioned plan of each pool and cross sections through it. They show depths, the waterline, inlets, main drains, suction outlets, gutters or skimmers, stairs and ladders.

  3. Recirculation schematic

    A flow diagram of pumps, filters, chemical feeders, heaters, surge tank, valves, gauges and flow meters. It also shows make-up water and backwash disposal, with pipe sizes taken from your engineer’s design.

  4. Equipment room and schedules

    The equipment room layout with space for installing and servicing each unit. Schedules list the pumps, filters, feeders and drain covers your engineer selected, drawn from the manufacturer’s data.

  5. Turnover and bather-load data

    A data sheet with surface area, volume, flow rate, turnover time and bather load or peak occupancy. We enter these figures exactly as your engineer calculated them.

  6. Deck, barrier and safety items

    Deck paving, slope and drains, the enclosure, gates and latching hardware. Depth markings, signs, safety equipment and accessible entries appear where the rule lists them and your designer places them.

WHO DOES WHAT

Who does what on a public pool submittal.

The drawings record decisions made by the people who are responsible for them.

Ask about your project →
  • You, the owner or developerYou hire the engineer or architect of record and decide which pools, spas and features the project includes. In South Carolina, for example, the owner must sign the construction permit application.
  • Your engineer or architectThey set the design, run the hydraulic and structural calculations, choose the equipment and answer the reviewer on technical points. Where the rule requires a seal, they direct the engineering and seal the set.
  • JEBNWe draft the plans, sections, schematics, schedules and data sheets from your designer’s work. When review comments come back, we redraw the sheets as your engineer directs.
  • The reviewing agencyA state or local health department, a building department or another agency named in your state’s law checks the submittal against its rules. The agency decides approval.
WHAT TO SEND

What to send for a plan-review drafting quote.

Send what you have now. Your free quote lists the sheets, the revisions included and the delivery date before you commit.

You do not need every document to request a quote. After the first reply, you can share files by email.

Open the project input checklist →
  • Your engineer’s designCalculations, sketches or marked-up sheets showing the pool layout, depths, pipe sizes, flow rates, turnover, bather-load figures and equipment choices.
  • Survey or site planA survey, civil site plan or architect’s floor plan showing where the pool, deck, enclosure and equipment room sit.
  • Manufacturer dataCut sheets for the pumps, filters, chemical feeders, drain covers, lifts and other listed items, so the schedules match what will be installed.
  • The agency’s checklistYour state or local agency’s plan-review checklist and application form. If the set was already submitted, send the review comments too.
FROM QUOTE TO DELIVERY

Three steps to your drawing set.

  1. Confirm the scope

    We review your request and reply by email within 24 hours with questions or a scoped quote. We identify missing inputs and what the reviewing agency asks for.

  2. Draft the set

    We draw the sheets listed in your quote from the design, details and measurements you send. Your quote states the delivery date.

  3. Deliver

    You receive the PDF set for your permit submission and the DWG files. Your quote states the revisions included. The reviewing agency decides approval and timing.

Who seals the drawings

JEBN prepares the drawings and does not seal them. Where your permit office or the reviewing agency requires a seal, a Professional Engineer licensed in your state, or an architect where the rule allows one, must direct the engineering and seal the set. The reviewing agency decides approval. If it sends comments, send them to us. Your quote states the revisions included.

How the engineer’s seal works →
Optional: 3D pool visualization

A 3D view can help you explore the proposed layout and materials. Ask to include it as a separate item alongside the drawing package.

BEFORE YOU ASK

Public pool plan review questions.

Who reviews public pool plans?

It depends on the state. In Washington, the state Department of Health or the local health officer reviews the permit application under WAC 246-260-021. In Iowa, the Department of Inspections, Appeals, and Licensing issues the construction permit for pools with more than 500 square feet of water surface. Florida law lets local governments review public pool plans against the Florida Building Code. Check your state’s rule, and ask your local building department whether a separate permit also applies.

Do public pool plans need an engineer’s seal?

It depends on the state, and several state rules require one. Washington asks for plans prepared, stamped and signed by an engineer or architect. Iowa’s rule 481 IAC 485.5(2) requires plans sealed by an engineer or architect licensed in Iowa. South Carolina law, section 44-55-2340, requires plans prepared and signed by an architect or engineer registered in the state. JEBN does not seal drawings, so the seal comes from your design professional.

Can you draft for the project’s engineer of record?

Yes. We draft the set from your engineer’s design, calculations and mark-ups, and we redraw sheets when review comments come back. Where your permit office or health department requires a seal, a Professional Engineer licensed in your state, or an architect where the rule allows one, must direct the engineering and seal the set. JEBN does not seal drawings.

What does the health department want in the submittal?

Each agency sets its own list. Washington’s and Iowa’s rules both ask for a site or overall plan, a scaled pool plan with cross sections, a piping schematic with pipe sizes and valves, an equipment layout and equipment specifications. Iowa also lists bathhouse drawings. Use your agency’s current checklist as the sheet list, and send it with your quote request so we can lay out the sheets to match the drawing items it lists.

Do you draw to the Model Aquatic Health Code?

The CDC’s Model Aquatic Health Code is voluntary guidance, not federal law. It becomes law only where a state, local, territorial or tribal jurisdiction adopts it, in whole or in part. New Mexico, for example, adopts the first edition by reference with its own changes. Where your jurisdiction uses it, we arrange the sheets around its plan submittal list, and your engineer applies its design requirements.

Do the drawings show drain safety and accessible entry?

The federal Virginia Graeme Baker Pool and Spa Safety Act requires anti-entrapment drain protection at public pools and spas, including pools open only to hotel guests or to apartment or HOA residents. Where the 2010 ADA Standards apply, a pool needs at least two accessible entries, one a lift or sloped entry. Under 300 linear feet of wall, one lift or sloped entry can be enough. We draw both as your engineer places them.

JEBN Engineering LLC. We draft pool drawings for US permit submissions.

View state pages